Torch Height Control for CNC Plasma Cutting: Analog vs Digital Sensing, Tuning, and Pierce Delay
This site's plasma cutting coverage so far is about handheld inverter cutters — choosing one, consumables, cut quality on steel you're cutting freehand or with a straightedge. A CNC plasma table is a different machine with a different core problem: steel plate is never perfectly flat, and a torch riding at a fixed Z height will gouge where the plate bows up and stand off too far (losing cut quality, or failing to pierce at all) where it dips down. Torch height control (THC) is the system that solves this by continuously adjusting torch-to-plate distance during the cut, and getting it right is the difference between a CNC plasma table that produces consistent parts and one that produces a different cut quality on every corner of every job.
Why Plasma Needs THC and a Router Doesn't
A CNC router's Z-axis is set once per job (or with a simple surface probe map, as covered in this site's Z-mapping guide) because a router bit cutting wood or plastic has real margin for a few thousandths of height variation. Plasma has essentially no such margin: cut quality, kerf width, and even whether the arc transfers and pierces at all are extremely sensitive to standoff height, and sheet steel plate commonly has enough warp, mill scale buildup, or simple table-mounting imperfection that a fixed Z height will produce a visibly different cut quality across a single sheet. THC exists specifically to measure and correct for that, continuously, while the torch is actually cutting — not just at the start of the job.
How THC Actually Senses Height
| Sensing Method | How It Works | Trade-offs |
|---|---|---|
| Arc voltage sensing (most common) | Measures the voltage across the plasma arc itself, which rises and falls predictably with torch-to-plate distance during a stable cut, and feeds that signal to a controller that moves the Z axis to hold a target voltage | No extra mechanical sensor needed at the torch; requires stable arc conditions to read correctly, and gets confused during pierce, corners, and cut-interruptions, which is why THC disables automatically during those events |
| Capacitive/inductive proximity sensing | A dedicated sensor measures physical distance to the plate directly, independent of arc electrical characteristics | More consistent through odd cutting conditions but adds a physical sensor and mounting complexity to the torch carriage |
| Mechanical float head | A spring-loaded torch mount physically rides on the plate surface, directly following its contour | Simple and cheap, but limited to lower cutting speeds and can be fooled by slag buildup or sharp plate edges |
Arc voltage sensing is what most hobbyist and small-shop CNC plasma controllers (Proma, CommandCNC, LinuxCNC's plasma component, and most dedicated plasma THC add-on boards) actually use, because it needs no extra sensor hardware at the torch and works across a very wide range of material thickness and amperage once the voltage-to-height relationship is characterized for your specific torch and consumables.
Tuning Arc Voltage THC
- Target voltage: set from your plasma cutter manufacturer's cut charts for your amperage and material thickness, then fine-tuned by cutting test coupons and checking actual kerf angle and dross — too high a target voltage means the torch rides too far from the plate (wider kerf, more dross on the bottom edge); too low means it rides too close (risk of double-arcing and consumable damage).
- Gain/response speed: too aggressive a correction response chases every small voltage fluctuation and can actually introduce height oscillation ("hunting"); too slow a response fails to correct for genuine plate warp fast enough and lets the torch drift out of tolerance across a long cut. Most THC controllers expose this as a tunable PID-style gain, and it needs adjusting for your specific torch mass and Z-axis mechanics, not just copied from someone else's settings.
- Hold-off and lockout windows: THC needs to be disabled during the pierce (where arc voltage is meaningless until the arc transfers and stabilizes) and briefly after sharp direction changes and at lead-in/lead-out, where voltage readings are transiently unreliable. Nearly every documented "THC randomly gouged my part" problem traces back to these lockout windows being too short or missing, letting the Z-axis chase a bad reading during exactly the moments it shouldn't be moving at all.
Pierce Delay and Its Relationship to THC
Pierce delay — the dwell time the torch holds position after arc transfer before cut motion begins — and THC are closely linked settings. The torch typically starts a pierce at a greater standoff height than the cutting height, then THC lowers it to cutting height once the pierce is complete and the arc has fully blown through the plate; if pierce delay is too short, the torch starts moving (and THC starts trying to follow height) before the material is actually fully pierced, dragging slag and producing an inconsistent start to the cut. Thicker plate needs a longer pierce delay, which is why pierce delay is set per material thickness in your CAM software's tool table (SheetCAM, covered elsewhere on this site, handles this directly) rather than as one global setting for every job.
Signs Your THC Needs Attention
| Symptom | Likely Cause |
|---|---|
| Consistent gouging at every corner | THC lockout window around direction changes too short, or disabled incorrectly |
| Visible height "chatter" mid-straight-cut | Gain set too aggressive, torch is oscillating height in response to normal arc voltage noise |
| Cut quality degrades gradually across a long cut on flat plate | Consumable wear changing the voltage-to-height relationship the THC was tuned for; re-tune or replace consumables and re-check target voltage |
| Torch crashes into the plate at pierce | Pierce height setting wrong, or THC engaging before pierce is complete |
Safety
A CNC plasma table combines high voltage, an open arc, and a Z-axis actively moving in response to electrical sensing — treat the torch head and its wiring with the same respect as any other live electrical equipment, keep THC sensor wiring shielded and away from the main power cabling to avoid false triggering from electrical noise, and never work on the torch head, Z-axis mechanics, or consumables with the plasma cutter's main power still live. Standard plasma cutting PPE (eye protection rated for the arc, fume extraction, and fire-safe clearance around the cutting area) applies on a CNC table exactly as it does for handheld cutting.
THC is the single system that separates a CNC plasma table that produces genuinely consistent cut quality from one that's fighting plate warp and mill scale on every job — it's worth tuning properly once, on real test coupons, rather than accepting default settings and blaming cut quality problems on the plasma cutter or consumables when the real issue is height control that was never actually dialed in.